PC based USB 8-Bit 100MSPS 40MHz Oscilloscope, Spectrum Analyzer, Signal Generator*
*Signal Generator function is available via the sound card or other DAC device, rather than the VT DSO-2810H unit
Find out more: Manual
General | |
---|---|
Sampling Frequency |
1. Single Channel, Maximum 60000 Samples* 100MHz, 50MHz, 20MHz, 10MHz, 5MHz, 2MHz, 1MHz, 500kHz, 200kHz, 100kHz, 50kHz, 20kHz, 10kHz 2. Single or Dual Channels, Maximum 30000 Samples per Channel 50MHz, 25MHz, 10MHz, 5MHz, 2.5MHz, 1MHz, 500kHz, 250kHz, 100kHz, 50kHz, 25kHz, 10kHz, 5kHz 3. Single or Dual Channels, Maximum 10000 Samples per Channel 2.5kHz 4. Single or Dual Channels, Maximum 500 Samples per Channel, work in Roll Mode** 50Hz, 25Hz, 5Hz |
Analog Bandwidth | 40MHz |
Number of Input Channels | 2 |
ADC Bit Resolution | 8 Bits |
Input Voltage Range | ± 40mV, ± 80mV, ± 200mV, ± 400mV, ± 800mV, ± 2V, ± 4V, ± 8V, ± 20V |
Maximum Allowed Input Voltage | ± 35V |
DC Accuracy | ± 3% |
Coupling Type | AC/DC |
Input Isolation | No |
Terminal Type | Referenced Single-Ended |
Buffer Size | 30000 bytes per Channel |
Sweep Time | 600µs~100s (with buffer fully filled) |
Trigger Source | CH1, CH2, EXT, ALT |
Trigger Level | Adjustable |
EXT Trigger Level | Adjustable in the range of -4V ~ 4V |
Trigger Edge | Rising, Falling |
Trigger Mode | Auto, Normal, Single |
Pre-Trigger | 0 ~ -100% |
Input Impedance | 1 MΩ , 25 pF |
Output Signal for Probe Calibration | 2Vpp, 1kHz, Square Wave |
Streaming Supported | No |
Interface | USB |
Casing | Internally shielded plastic |
Device Category in Multi-Instrument | VT DSO H1 |
Power | Bus powered by USB port, no external power source required |
Power Consumption | Max. 2.5W |
Dimensions | 203 mm (L) x 99 mm (W) x 33 mm (H) |
System Requirement | Windows XP, Vista, 7, 8, 8.1, 10 or 11, 32 bit or 64 bit |
*Some of these frequencies are not listed in the sampling frequency selection combo box of the Multi-Instrument software. You need to stop the oscilloscope, enter the sampling frequency value
directly into that combo box and then set the number of sampling channels to single, if you need to use these sampling frequencies.
**Under these sampling frequencies, adjusting the trigger mode, trigger source, trigger edge, trigger level, trigger delay will have no impact on the sampling.
General | |
---|---|
Attenuation Ratio | x 1, x 10 |
Bandwidth (-3dB) | DC ~ 60 MHz (x 10), DC ~ 6 MHz (x 1) |
Input Impedance | 10 MΩ (x 10, with VT DSO-2810H connected) 1 MΩ (x 1, with VT DSO-2810H connected) |
Input Capacitance | 18.5 pF~22.5 pF (x 10), 85 pF~ 115 pF (x 1) |
Input Capacitance Compensation Range | 15 ~ 40 pF |
Length | 1.2 m |
Accessories include: a 6" snap-on rotating ground lead, a sprung hook, two marker rings, a probe compensation adjustment tool, two probe tip caps.