Click here to download and try the fully functional Multi-Instrument software using your sound card as the ADC and DAC device!
PC USB 24-bit dual-channel 48 kSPS 0.03Hz~23kHz Data Acquisition Interface with Charge Input / Digital Charge Amplifier
VT CAMP-2G05 is a 24-bit, dual-channel, USB data acquisition interface specially designed for use with sensors with electric charge output such as piezoelectric sensors. Each channel has a built-in charge amplifier with 12 calibrated charge measurement ranges for easy calibration to sensor sensitivity: ± 250 pC, ± 500 pC, ± 1 nC, ± 2.5 nC, ± 5 nC, ± 10 nC, ± 25 nC, ± 50 nC, ± 100 nC, ± 250 nC, ± 500 nC, ± 1 µC. High-precision capacitors with low dissipation factors, low dielectric absorptions and very constant capacitance values against temperature and humidity variation are used in the charge amplifiers to convert charge to voltage. The charge amplifiers are equipped with an overload indicator and a reset facility. Each channel contains a hardware high-pass filter with 5 selectable -3dB corner frequencies: None (0.03 Hz), 1.8 Hz, 119 Hz, 236 Hz and 464 Hz. The signals sensed by the charge-output sensors can be amplified and output directly from the stereo headphone jack even without running the PC software. When used in conjunction with the Multi-Instrument® software, the setup allows you to take reliable and quality vibration and noise measurements as simply as plug & play. No external power supply and driver installation is required. It is a truly hassle-free portable vibration and noise test & measurement solution.
VT CAMP-2G05A has the same specifications as VT CAMP-2G05, except that its Channel B has a 60 dB higher analog gain, with its charge measurement ranges changed to: ± 250 fC, ±500 fC, ± 1 pC, ± 2.5 pC, ± 5 pC, ± 10 pC, ± 25 pC, ± 50 pC, ± 100 pC, ± 250 pC, ± 500 pC, ± 1 nC. The increased gain makes it more capable of measuring low level signals such as a low-dB sound in water.
VT CAMP-2G05B has the same specifications as VT CAMP-2G05, except that its two input channels A & B have a 60 dB higher analog gain, with their charge measurement ranges changed to: ± 250 fC, ± 500 fC, ± 1 pC, ± 2.5 pC, ± 5 pC, ± 10 pC, ± 25 pC, ± 50 pC, ± 100 pC, ± 250 pC, ± 500 pC, ± 1 nC. The increased gain makes it more capable of measuring low level signals such as a low-dB sound in water.
It is possible to run multiple VT CAMP-2G05/A/B using multiple instances of the software on the same computer.
Find out more: Manual
Note: It is possible to place most add-on items inside the same carrying case with VT CAMP-2G05/A/B.
General | ||
---|---|---|
Number of Input Channels | 2 | |
Sampling Frequency | 48 kHz (original), 44.1 kHz, 32 kHz, 22.05 kHz, 16 kHz, 11.025 kHz, 8 kHz, 4 kHz, 2 kHz ... | |
ADC Bit Resolution | 24 Bits (can be reduced to 16 bits or 8 bits) | |
Input Charge Ranges | CAMP-2G05: ± 250 pC, ± 500 pC, ± 1 nC, ± 2.5 nC, ± 5 nC, ± 10 nC, ± 25 nC, ± 50 nC, ± 100 nC, ± 250 nC, ± 500 nC, ± 1 µC |
|
CAMP-2G05A: Ch.A: ± 250 pC, ± 500 pC, ± 1 nC, ± 2.5 nC, ± 5 nC, ±10 nC, ± 25 nC, ± 50 nC, ± 100 nC, ± 250 nC, ± 500 nC, ± 1 µC Ch.B: ± 250 fC, ± 500 fC, ± 1 pC, ± 2.5 pC, ± 5 pC, ±10 pC, ± 25 pC, ± 50 pC, ± 100 pC, ± 250 pC, ± 500 pC, ± 1 nC |
||
CAMP-2G05B: ± 250 fC, ± 500 fC, ± 1 pC, ± 2.5 pC, ± 5 pC, ± 10 pC, ± 25 pC, ± 50 pC, ± 100 pC, ± 250 pC, ± 500 pC, ± 1 nC |
||
Input Connectors & Interface | BNC, Single Ended | |
Input Coupling Type | AC (High-pass filtered at 0.03 Hz) | |
Input Isolation | No (Isolation can be achieved through a USB isolator) | |
(Voltage) Input Impedance | 1 kΩ | |
Input High Pass Filter | None, 1.8 Hz, 119 Hz, 236 Hz, 464 Hz | |
Charge Amplifier Time Constants | CAMP-2G05: 1210 s (6 Higher Ranges), 12.1 s (6 Lower Ranges) |
|
CAMP-2G05A: Ch.A: 1210 s (6 Higher Ranges), 12.1 s (6 Lower Ranges) Ch.B: 1.21 s (6 Higher Ranges), 0.0121 s (6 Lower Ranges) |
||
CAMP-2G05B: 1.21 s (6 Higher Ranges), 0.0121 s (6 Lower Ranges) |
||
Frequency Response | CAMP-2G05: 0.03 Hz ~ 22.8 kHz |
|
CAMP-2G05A: Ch.A: 0.03 Hz ~ 22.8 kHz Ch.B: 0.13Hz ~ 22.8 kHz (6 Higher Ranges); 13 Hz ~ 22.8 kHz (6 Lower Ranges) |
||
CAMP-2G05B: 0.13Hz ~ 22.8 kHz (6 Higher Ranges); 13 Hz ~ 22.8 kHz (6 Lower Ranges) |
||
Frequency Accuracy | 50 PPM | |
Anti-aliasing Filter | 22.8 kHz at Sampling Rate 48 kHz, proportionally adaptive to Sampling Rate Chosen | |
Buffer Size | Virtually unlimited (streaming mode) | |
Charge Accuracy | ±0.5% at 1000Hz (FS>=250pC); ±2% at 1000Hz (FS<250pC); | |
Output Connector & Interface | ϕ3.5 mm Stereo Audio Jack | |
Output Voltage Range | ±0.5 V | |
Digital Input / Output Standard | USB Audio Class 1 | |
Calibration | Individually done at factory, user re-calibratable | |
PC Interface | USB 2.0 Full Speed / USB 1.1 | |
Device Category in Multi-Instrument | ADC Device | Sound Card MME |
DAC Device | Not Applicable | |
Power | Bus powered by USB port, no external power source required | |
Power Consumption | Max. 0.5W | |
Dimensions | 128 mm (L) X 57 mm (W) X 24 mm (H), anodized aluminum case | |
Operating Temperature | 0° C ~50° C | |
System Requirements | Windows XP, Vista, 7, 8, 8.1, 10, 11, 32 bit or 64 bit |