VT-RTA-268ABC slide

Buy VT RTA-268A/B/C

VT RTA-268
VT RTA-268A (US$999.95)

PC based USB Ultra-Low Noise Real Time Acoustic Analyzer, Sound Level Meter, Distortion Analyzer, Polarity Tester, Time Delay Finder
Hardware Configuration
Measurement Microphone: M215
XLR-to-USB Audio Interface: UAC-232

VT RTA-268
VT RTA-268B (US$999.95)

PC based USB Ultra-Low Noise Real Time Acoustic Analyzer, Sound Level Meter, Distortion Analyzer, Polarity Tester, Time Delay Finder
Hardware Configuration
Measurement Microphone: M215L
XLR-to-USB Audio Interface: UAC-232

VT RTA-268
VT RTA-268C (US$2199.95)

PC based USB Ultra-Low Noise Real Time Acoustic Analyzer, Sound Level Meter, Distortion Analyzer, Polarity Tester, Time Delay Finder
Hardware Configuration
Measurement Microphone: M50
XLR-to-USB Audio Interface: UAC-232

Introduction

VT RTA-268A/B/C is a series of PC-based ultra-low-noise huge-dynamic-range real-time acoustic analyzers, powered by the comprehensive virtual instrument software, Multi-Instrument®. The USB audio interface used in the analyzers has two ADCs working in tandem to create a single output data stream in 32-bit float format. One "low gain" ADC is optimized for high-level signals, and the other "high gain" ADC is optimized for low-level signals. This state-of-the-art dual-ADC architecture provides unmatchable dynamic range compared with the conventional single ADC approach. With a proper microphone, it is now possible to capture sound across the entire human hearing range without sacrificing fidelity at low signal levels or encountering clipping at high signal levels, and this can be achieved without the hassle of manual analog gain adjustment and measurement range switching at all.

VT RTA-268A comes with M215 measurement microphone.
VT RTA-268B comes with M215L measurement microphone.
VT RTA-268C comes with M50 measurement microphone.

All these microphones have an extremely flat frequency response in their rated frequency ranges. Each M50 also comes with its unique frequency response file, which can be used in the software to further improve the accuracy.
Find out more: Manual

M215
M215
M215L
M215L
M50
M50

Package Contents

  1. XLR Measurement microphone and its accessories (a windshield, a microphone clip and a small microphone stand)
  2. XLR-to-USB Audio Interface
  3. USB cable (1 m)
  4. XLR cable (1.5 m)
  5. CD (contains the copy-protected Multi-Instrument Software)
  6. USB hardkey (contains a Multi-Instrument Pro License)
  7. Audio Test WAV files (contains a list of audio test tones and noises)
    Download Link: AudioTestCD.rar, AudioTestCD.zip
  8. Carrying Case
  9. Unique Sound Level Calibration Data (in CD)
  10. Unique Microphone Calibration Data (in CD, only applicable to RTA-268C)

Unique Calibration File Download:

RTA-268A Mic Serial Number M215-XXXXXX
RTA-268B Mic Serial Number M215L-XXXXXX
RTA-268C Mic Serial Number M50-XXXXX
Other Customized Configuration: V210-XXXX-XXXX-XXXX


Add-on Items

  1. An additional XLR measurement microphone and its accessories
  2. P48-to-IEPE converter (so that IEPE sensors can be connected to the XLR input)
  3. IEPE sensors
  4. Software license upgrade

Overall VT RTA-268A/B/C Specifications

General RTA-268A RTA-268B RTA-268C
Frequency Range 20Hz ~ 31.5kHz 20Hz~20kHz 9Hz~50kHz
Sound Level Measurement Range 20dB ~ 126dB 22dB~138dB 22dB~128dB
Sampling Rate 44.1kHz, 48kHz, 88.2kHz, 96kHz, 176.4kHz, 192kHz
Bit Depth 32-bit Float / 24-bit
Number of Input Channels 2
Number of Output Channels 2
Frequency Accuracy 0.001%
Frequency Weighting Flat, A, B, C, Z, ITU-R 468
Time Weighting Linear, Exponential
(Equivalent Continuous Sound Level (Leq) fully complies with IEC61672)
Sound Level Measurement Accuracy ± 0.3 dB at 94dB, 1kHz after calibration
Sound Level Calibration Calibrated using Type 1 Sound Level Calibrator
Octave Analysis 1/1, 1/3, 1/6, 1/12, 1/24, 1/48, 1/96 (Complies with IEC61260)
Other Functions THD, THD+N, SINAD, SNR, SMPTE IMD, DIN IMD, CCIF2 IMD, Frequency Response, RT60, etc.
Much more functions are described in the software manual.
USB Interface USB 2.0
USB Audio USB Audio Class 2.0 (driver installation required)
Power Supply USB bus powered (5V)
System Requirements Windows 10/11, 64 bit. Minimum Screen Resolution: 1024 x 600
Calibration Individually calibrated

UAC-232 Audio Interface Specifications

Input Input Impedance Max. Voltage Dynamic Range XLR Phantom Power
Left (Input 1):
XLR/TRS/TS(HiZ) Combo Jack
XLR: 2.7 kΩ

TRS: 4 kΩ / 1MΩ (when HiZ on)
XLR: 2.35 Vp

TRS: 23.0 Vp / 4.30 Vp (when HiZ on)
XLR: 134 dB

TRS: 129 dB
TS(HiZ): 123dB
48V
Right (Input 2):
XLR/TRS Combo Jack
Output Output Impedance Max. Voltage
Left (Output 1): TRS (balanced) Jack 100 Ω 9.0 Vp
(adjustable through volume knob)
Right (Output 2): TRS (balanced) Jack
Headphone 12Ω 4.4 Vp
(adjustable through volume knob)
General
MIDI IN/OUT (5-pin DIN connectors)
Input Frequency Response 44.1 kHz: 20Hz~20kHz, +0.1 dB / -0.2 dB
-3dB: 9Hz~21.8kHz

48 kHz: 20Hz~20kHz, ±0.21dB
-3dB: 9Hz~23.8kHz

96 kHz: 20Hz~40kHz, ±0.22dB
-3dB: 9Hz~47.6kHz

192 kHz: 20Hz~80kHz, +0.1 dB / -0.2 dB
-3dB: 9Hz~91.8kHz
TRS Output Frequency Response 44.1 kHz: 20Hz~20kHz, +0.0 dB / -0.1 dB
192 kHz: 20Hz~80kHz, +0.0 dB / -1.0 dB
Headphone Output Frequency Response 44.1 kHz: 20Hz~20kHz, +0.0 dB / -0.5 dB
192 kHz: 20Hz~80kHz, +0.0 dB / -1.0 dB
USB Connector Type C
Power Consumption Max. 2.5W
Dimension 164 mm (W) x 105.5 mm (D) x 65 mm (H)
Weight 355g
Typical Magnitude Frequency Response of XLR Input @ Sampling Rate 192kHz

Typical Magnitude Frequency Response of XLR Input @ Sampling Rate 192kHz

THD, THD+N, SNR, SNAD, ENOB of XLR Input @ 1kHz, 1Vp

THD, THD+N, SNR, SNAD, ENOB of XLR Input @ 1kHz, 1Vp

SMPTE IMD of XLR Input @ 1Vp

SMPTE IMD of XLR Input @ 1Vp

Measurement Microphone M215 Specifications (for VT RTA-268A)

General
Transducer Type 1/2" low-noise pre-polarized condenser
Polar Pattern Omni-directional
Sensitivity (±2dB) 40 mV/Pa
Frequency Response 20Hz ~ 31.5kHz
Power Supply 48V Phantom Power
Max. SPL (<1% THD) 135dB
Equivalent Noise Level <18 dBA
Output Impedance <75Ω
Temperature Coefficient (dB/℃) 0.009
Humidity Coefficient (dB/%RH) 0.001
Pressure Coefficient (dB/kPa) 0.008
Length 155mm
Weight 120g
Connector 3-pin XLR
Compliance IEC 61094 and IEC 61672 Class 1
Typical Polar Pattern of M215

Typical Polar Pattern of M215

Typical Frequency Response of M215

Typical Frequency Response of M215

Measurement Microphone M215L Specifications (for VT RTA-268B)

General
Transducer Type 1/2" low-noise pre-polarized condenser
Polar Pattern Omni-directional
Sensitivity (±2dB) 10 mV/Pa
Frequency Response 20Hz~20kHz
Power Supply 48V Phantom Power
Max. SPL (<1% THD) 145dB
Equivalent Noise Level <20 dBA
Output Impedance <75 Ω
Temperature Coefficient (dB/℃) 0.009
Humidity Coefficient (dB/%RH) 0.001
Pressure Coefficient (dB/kPa) 0.008
Length 155mm
Weight 120g
Connector 3-pin XLR
Compliance IEC 61094 and IEC 61672 Class 1

Measurement Microphone M50 Specifications (for VT RTA-268C)

General
Transducer Type Small Diaphragm low-noise pre-polarized conderser
Polar Pattern Omni-directional
Sensitivity (Typical) 34 mV/Pa
Frequency Response 3Hz ~ 50kHz
Power Supply 24~48V Phantom Power, 10mA
Max. SPL 140dB
Equivalent Noise Level <20 dBA
Output Impedance 65Ω
Minimum Output Load 600Ω
Dimension 229 x 22mm
Weight 225g
Connector 3-pin XLR
Typical Polar Pattern of M50

Typical Polar Pattern of M50

Typical Frequency Response of M50

Typical Frequency Response of M50

Note: This is only a typical frequency response chart. The measurement microphone M50 is calibrated individually and the calibration data is included in the product package.

Examples

Magnitude-Frequency-Response-using-Pseudo-Pink-Noises
Magnitude Frequency Response Measurement using Octave Analysis with Periodic Pink Noise Excitation (no averaging is required unlike the case of pink noise)
RT60-InterruptedNoiseMethod
Measurement of Reverberation and Its Related Acoustic Parameters using the Interrupted Noise Method (Note: Multi-Instrument Pro or above is required)
RT60-Integrated-Impulse-Response-Method
Measurement of Reverberation and Speech Intelligibility Parameters using the Integrated Impulse Response Method (Note: Multi-Instrument Pro or above is required)
RT60-STI-Integrated-Impulse-Response-Method
(cont.) Measurement of Reverberation and Speech Intelligibility Parameters using the Integrated Impulse Response Method (Note: Multi-Instrument Pro or above is required)
Glitch_Detection
Discontinuity Measurement for Detection of Glitch, Digital Dropout, Speaker Rub and Buzz (Note: Multi-Instrument Pro or above is required)
White-Noise-Loudness-Loudness-Level-Sharpness
Sound Quality Measurement Example - Loudness, Loudness Level, Sharpness of a white noise in a Free Field (Note: Multi-Instrument Pro or above is required)
Time-Delay-Measurement-Using-Generalized-Cross-Correlation
Live Music Broadcast Latency Measurement using Generalized Cross Correlation with Software-Switchable Mixer-Level Loopback As Time Reference