Model |
Description |
Unit Price
Free Express Shipping |
AEC-6160 |
IEC-318 Artificial Ear AEC-6160
. Frequency Range:
20Hz~10000Hz . Frequency Response Accuracy against
Standard (e.g. BK4153): ≤ ±1
dB (20Hz~10000Hz), see
comparison . Compliance: IEC 60318-1 (formerly
IEC 318 and IEC 60318) . 1/2"
measurement mic supported . For supra-aural and
circumaural earphone testing |
US$499.95
|
AEC-6160-MIC |
IEC-318 Artificial Ear with
IEPE Microphone AEC-6160-MIC
. Frequency Range:
20Hz~10000Hz . Frequency Response Accuracy against
Standard (e.g. BK4153): ≤ ±1
dB (20Hz~10000Hz), see
comparison . Compliance: IEC 60318-1 (formerly
IEC318 and IEC 60318) .
Includes a 1/2", 30mV/Pa, IEC 61094-4 pressure-field IEPE
measurement microphone that meets the stringent standards not
found in consumer or even professional audio products. The
output connector is BNC by default. . For supra-aural
and circumaural earphone testing
|
US$949.95
|
AEC-6161 |
IEC-126 2cc Acoustic Coupler
AEC-6161
. Frequency Range:
125Hz~8000Hz . Frequency Response Accuracy against
Standard: ≤ ±0.5dB (200Hz~5000Hz), ≤ ±1
dB (125Hz~8000Hz) . Compliance: IEC 60318-5 (formerly
IEC 126 and IEC 60126) . 1/2"
and 1" measurement mic supported . For insert type
hearing aids and earphone testing |
US$229.95
|
AEC-6161-MIC |
IEC-126 2cc Acoustic
Coupler with IEPE Microphone AEC-6161-MIC
. Frequency Range:
125Hz~8000Hz . Frequency Response Accuracy against
Standard: ≤ ±0.5dB (200Hz~5000Hz), ≤ ±1
dB (125Hz~8000Hz) . Compliance: IEC 60318-5 (formerly
IEC 126 and IEC 60126) .
Includes mounting base . Includes a 1/2", 30mV/Pa, IEC
61094-4 pressure-field IEPE measurement microphone that meets
the stringent standards not found in consumer or even
professional audio products. The output connector is BNC by
default. . For insert type hearing aids and earphone
testing
|
US$749.95
|
AEC-6162-MIC |
IEC-711 Artificial Ear with
IEPE Microphone AEC-6162-MIC
. Frequency Range:
20Hz~10000Hz . Frequency Response Against Standard
(e.g. BK4195): ≤ ±0.5dB (200Hz~5000Hz), ≤ ±1
dB (20Hz~10000Hz), see
comparison . Compliance: IEC 60318-4 (IEC 711
and IEC 60711) .
Includes mounting base . Includes a 1/2", 30mV/Pa, IEC
61094-4 pressure-field IEPE measurement microphone that meets
the stringent standards not found in consumer or even
professional audio products. The output connector is BNC by
default. . For insert type hearing aids and earphone
testing |
US$1099.95
|
AEC-6163-MIC |
IEC-303 6cc Artificial Ear
with IEPE Microphone AEC-6163-MIC
. Frequency Range:
100Hz~8000Hz . Frequency Response Against Standard
(BK4152): ≤ ±0.5dB (200Hz~5000Hz), ≤ ±1
dB (100Hz~8000Hz) . Compliance: IEC 60318-3 (formerly
IEC 303 and IEC 60303, NBS9A) .
Includes a 1", 100mV/Pa, IEC 61094-4 pressure-field IEPE
measurement microphone that meets the stringent standards not
found in consumer or even professional audio products. The
output connector is BNC by default. . For audiometer
testing |
US$1449.95
|